Calculators
35 calculators for the arithmetic that comes up on real jobs. Every one shows its work, names the table value it used, and states what it does not account for, so a qualified person can check it rather than trust it.
Electrical
Control Panels
Instrumentation
PLC & Data
Networking
Water & Wastewater
Conversions
Reference tables
The lookup tables behind several of these calculators, published separately so the values can be read directly.
- Conductor Ampacity TableAllowable ampacity for copper and aluminum conductors at the 60, 75, and 90 degree C columns, for not more than three current-carrying conductors at 30 degrees C ambient.
- Ambient Temperature Correction FactorsMultipliers applied to conductor ampacity when the ambient temperature differs from 30 degrees C, by insulation temperature rating.
- Adjustment Factors for Conductor CountAmpacity multipliers applied when more than three current-carrying conductors share a raceway or cable.
- Wire Gauge, Circular Mils, and AreaCircular mil area and approximate insulated cross-sectional area for AWG and kcmil conductor sizes.
- Three-Phase Motor Full-Load CurrentFull-load current for three-phase induction motors by horsepower and voltage, used for sizing conductors and overcurrent devices.
- Standard Overcurrent Device RatingsThe standard ampere ratings for fuses and inverse-time circuit breakers, used when rounding a calculated value to an available device.
- Conduit Internal Area by Type and Trade SizeInternal cross-sectional area of EMT, ENT, FMC, IMC, LFMC, LFNC-B, RMC, and Schedule 40 and 80 PVC by trade size, the figure conduit fill is measured against.
- Insulated Conductor Area by Insulation TypeApproximate cross-sectional area of THHN, XHHW, TW, THW, and RHW conductors from 14 AWG to 1000 kcmil, the figures that are summed for conduit fill.
- PLC Data Type RangesBit width and value range for the IEC 61131-3 elementary data types, with the practical notes that matter in controller programming.
- 4-20 mA Signal ReferenceCurrent, percent of span, and voltage across a 250 ohm input for a 4-20 mA loop, including the NAMUR fault thresholds.
- Enclosure Type RatingsWhat each enclosure type rating protects against, and where each is normally used in controls work.
- Controls Unit Conversion ReferenceThe conversions that come up constantly in controls and water work: pressure, flow, level, power, and temperature.
Direct contact
Have a controls question?
Reach Eric Sullivan directly about anything on this site, a controls or automation topic, or one of his personal projects.
Content on CurryControls.com is general technical reference information provided for educational and reference purposes only. It is not engineering advice for a specific installation. All information must be independently verified against current codes, standards, manufacturer documentation, project requirements, and qualified professional judgment before it is relied upon or applied.