How-To

Step-by-step procedures for the tasks that come up on real jobs. Each one is written to be worked through with the equipment in front of you.

36 topics31 written guides

Written guides in this section

Full references, procedures, and diagnostic guides published under How-To.

How-ToHow-ToPLC

How to Build a Sequencer

Build a step sequencer in a controller that will not stick, restart into the wrong step, or leave equipment half way: define the steps from the narrative, choose a step register, and test every path before the plant depends on it.

9 min readUpdated Sep 5, 2026

How-ToModbusPLC

How to Configure a Modbus Connection

Set up a Modbus RTU or TCP link between a controller and a device: get the register map, match the physical and protocol settings, build the reads and writes, handle data types and the addressing offset, and verify with a protocol tool before trusting a value.

10 min readUpdated Sep 5, 2026

How-ToHow-ToCommunications

How to Diagnose Read and Write Communications

Diagnose a controller that cannot read from or write to a device: capture the exact request and response, classify the failure as no link, no answer, or a rejected exchange, read the error or exception code, compare with a test tool, and fix the port.

8 min readUpdated Sep 5, 2026

How-ToPLCPID

How to Create a PID Loop in a PLC

Set up a PID instruction from scratch: scale the PV and CV, pick the action, set the execution rate, configure limits and anti-windup, tune conservatively, and test the manual and auto transitions before it controls anything.

10 min readUpdated Sep 5, 2026

How-ToAlarmsPLC

How to Add an Alarm

From a request to a working alarm: define it against the philosophy, build the condition in the PLC with deadband and delays, configure the SCADA alarm with priority and message, test it end to end, and record it in the master alarm database.

9 min readUpdated Sep 5, 2026

How-ToHow-ToPLC

How to Configure Remote I/O

Add a remote I/O rack to a controller over Ethernet: plan the network and addresses, set the adapter, and prove every point and the failure behavior before the rack goes into service.

8 min readUpdated Sep 5, 2026

Browse How-To

Direct contact

Have a controls question?

Reach Eric Sullivan directly about anything on this site, a controls or automation topic, or one of his personal projects.

References to manufacturers, products, model numbers, software platforms, technical specifications, companies, standards organizations, or other organizations are provided for informational purposes and do not imply sponsorship, endorsement, authorization, or affiliation unless expressly stated. Manufacturer specifications must be independently verified against current manufacturer documentation.