CURRYCONTROLS.COMControls & Automation Knowledge Hub

Controls

PLC Systems

Architecture, programming, analog control, communications, and troubleshooting for programmable logic controllers.

63 topics55 written guides

Written guides in this section

Full references, procedures, and diagnostic guides published under PLC Systems.

ReferencePLCFundamentals

PLC Architecture

How a programmable logic controller is physically organized: the chassis, backplane, processor, I/O modules, remote racks, and what those choices mean for wiring, expansion, and failure.

8 min readUpdated Sep 5, 2026

ReferencePLCFundamentals

The PLC Processor

What the processor module does on every scan, how its memory is organized, what the mode switch and status lights mean, and how it faults and recovers.

8 min readUpdated Sep 5, 2026

ReferencePLCPanels

Control Power Supplies

Sizing the 24 VDC supplies that run a controller and its field devices, separating loads that should not share a supply, and keeping the controller alive through a power event.

8 min readUpdated Sep 5, 2026

ReferencePLCFundamentals

PLC I/O Systems

Discrete and analog input and output modules, sinking and sourcing, relay and transistor outputs, wiring conventions, and the module diagnostics that find field faults from the panel.

9 min readUpdated Sep 5, 2026

ReferencePLCFundamentals

Controller Memory and Addressing

How a controller organizes its data: data tables and tags, the input and output images, the elementary data types and what they hold, and the naming discipline that keeps a program readable years later.

8 min readUpdated Sep 5, 2026

ReferencePLCFundamentals

Tasks and Execution Priority

How a controller schedules its work: the continuous task, periodic tasks at a fixed rate, event tasks triggered by something happening, how priority preempts, and where each kind of logic belongs.

7 min readUpdated Sep 5, 2026

Topics in this area

Direct contact

Have a controls question?

Reach Eric Sullivan directly about anything on this site, a controls or automation topic, or one of his personal projects.

References to manufacturers, products, model numbers, software platforms, technical specifications, companies, standards organizations, or other organizations are provided for informational purposes and do not imply sponsorship, endorsement, authorization, or affiliation unless expressly stated. Manufacturer specifications must be independently verified against current manufacturer documentation.