CURRYCONTROLS.COMControls & Automation Knowledge Hub

How-To

Panel How-To

Panel How-To in industrial control systems — covering 6 topic areas in the CurryControls.com controls and automation knowledge hub.

6 topics6 written guides

Written guides in this section

Full references, procedures, and diagnostic guides published under Panel How-To.

How-ToHow-ToPanels

How to Select Surge Protection

Select the surge protective devices for a control panel and its field circuits: list every conductor that enters, classify its exposure, choose the device type and ratings for the power, the loops, and write it into the drawings and the I/O list.

8 min readUpdated Sep 5, 2026

How-ToHow-ToPanels

How to Size an Enclosure

Size a control panel enclosure so that everything fits, cools, and can be worked on: lay out the components with their clearances and wireway, add the spare space the plant will need, and mounting before ordering.

8 min readUpdated Sep 5, 2026

How-ToPanelsUL 508A

How to Calculate a Panel SCCR

Determine the short-circuit current rating of a control panel by the UL 508A Supplement SB method: list every power circuit component, find each rating, apply published series combinations and current limiting, and mark the panel with the lowest result.

10 min readUpdated Sep 5, 2026

How-ToHow-ToPanels

How to Build Terminal Schedules

Produce the terminal schedule that lets a technician find any wire: define the strips and their numbering, list every terminal with its wire numbers, the device and the field destination, and keep it current through every change.

7 min readUpdated Sep 5, 2026

How-ToHow-ToGrounding

How to Design Panel Grounding

Design the grounding and bonding of a control panel and its site so that faults clear, signals are clean, and surges have a path: bond the enclosure and everything in it, and verify with measurements before the panel is energized.

8 min readUpdated Sep 5, 2026

How-ToPanelsHow-To

How to Size a Control Panel Power Supply

Add up the real load, account for inrush and simultaneity, add headroom, and check the heat you just added to the enclosure.

7 min readUpdated Aug 14, 2026

Topics in this area

Direct contact

Have a controls question?

Reach Eric Sullivan directly about anything on this site, a controls or automation topic, or one of his personal projects.

References to manufacturers, products, model numbers, software platforms, technical specifications, companies, standards organizations, or other organizations are provided for informational purposes and do not imply sponsorship, endorsement, authorization, or affiliation unless expressly stated. Manufacturer specifications must be independently verified against current manufacturer documentation.