How to Calibrate a Pressure Transmitter
A five-point calibration with a pressure source and a reference: isolate and vent, record as-found, decide whether to adjust, trim the sensor and the output separately, verify as-left, and record it so the next calibration means something.
9 min readUpdated Sep 5, 2026
How to Diagnose a Ground Loop
Prove that a noisy or offset analog signal is a ground loop, find the second ground, and fix it the right way: remove the extra ground, isolate the signal, or correct the shield termination. With the measurements that make the diagnosis certain.
9 min readUpdated Sep 5, 2026
How to Configure a Radar Level Transmitter
Commission a non-contact radar on a wet well or tank: mount it, set the reference and range from measured elevations, map false echoes with the vessel empty, set damping and the output, and verify against a tape at two levels before the controller uses it.
9 min readUpdated Sep 5, 2026
How to Troubleshoot a Flowmeter
Work a flowmeter that reads wrong, reads zero, or reads with the pipe still: confirm the pipe is full and the flow is real, check the installation against the meter requirements, and compare against an independent measurement before adjusting anything.
9 min readUpdated Sep 5, 2026
How to Test a 4-20 mA Loop
Prove a current loop end to end with a meter and a calibrator, without interrupting a process you were not authorized to interrupt.
8 min readUpdated Aug 6, 2026
Topics in this area
Calibrate a Pressure Transmitter
Calibrate a Pressure Transmitter — practical reference notes for controls engineers, integrators, and technicians working with instrumentation how-to.
Test a 4-20 mA Loop
Prove a loop end to end with a meter and a calibrator, without lifting the wrong wire.
Diagnose Ground Loops
Diagnose Ground Loops — practical reference notes for controls engineers, integrators, and technicians working with instrumentation how-to.
Configure Radar Level
Configure Radar Level — practical reference notes for controls engineers, integrators, and technicians working with instrumentation how-to.
Troubleshoot a Flowmeter
Troubleshoot a Flowmeter — practical reference notes for controls engineers, integrators, and technicians working with instrumentation how-to.
Direct contact
Have a controls question?
Reach Eric Sullivan directly about anything on this site, a controls or automation topic, or one of his personal projects.
References to manufacturers, products, model numbers, software platforms, technical specifications, companies, standards organizations, or other organizations are provided for informational purposes and do not imply sponsorship, endorsement, authorization, or affiliation unless expressly stated. Manufacturer specifications must be independently verified against current manufacturer documentation.