Skip to main content
Call Eric:863-698-8266
CURRYCONTROLS.COMControls & Automation Knowledge Hub

Controls › PLC Systems

Programming

The five IEC languages and the structures that make a program maintainable.

12 topics12 written guides

Written guides in this section

Full references, procedures, and diagnostic guides published under Programming.

ReferencePLCProgramming

Function Block Diagram

The graphical data-flow language of IEC 61131-3: how blocks, pins, and wires work, execution order, where FBD beats ladder and structured text, building reusable equipment blocks, and the habits that keep a diagram readable.

9 min readUpdated Sep 5, 2026

ReferencePLCProgramming

Structured Text

The text language of IEC 61131-3: syntax, control structures, how it fits alongside ladder, the conventions that keep it readable for the next person, and the mistakes that make structured text a liability in a plant that troubleshoots online.

10 min readUpdated Sep 5, 2026

ReferencePLCProgramming

Sequential Function Chart

The IEC 61131-3 language for sequences: steps, transitions, actions and their qualifiers, alternative and simultaneous branches, where it fits in water and wastewater, and the rules that keep a chart from sticking in a step.

9 min readUpdated Sep 5, 2026

ReferencePLCProgramming

IEC 61131-3

The standard behind PLC programming languages: the five languages, the common elements of data types, variables, and program organization units, what conformance actually means, and how the standard shows up in real platforms.

9 min readUpdated Sep 5, 2026

ReferencePLCProgramming

Program Organization

Structuring a controller program so that someone else can maintain it: a layout that follows the plant, one routine per job, standard device blocks, I/O mapped in one place, a fixed execution order, naming that means something, and comments that say why.

10 min readUpdated Sep 5, 2026

ReferencePLCProgramming

State Machines in PLC Programs

Writing sequences as explicit states instead of tangled interlock chains: what a state is, how transitions are written, the pattern in structured text and in ladder, publishing the state to the HMI, and the failure handling every state machine needs.

11 min readUpdated Sep 5, 2026

Topics in this area

Direct contact

Have a controls question?

Reach Eric Sullivan directly about anything on this site, a controls or automation topic, or one of his personal projects.

References to manufacturers, products, model numbers, software platforms, technical specifications, companies, standards organizations, or other organizations are provided for informational purposes and do not imply sponsorship, endorsement, authorization, or affiliation unless expressly stated. Manufacturer specifications must be independently verified against current manufacturer documentation.