Controls › PLC Systems

Communications

The protocols that move data between controllers, devices, and SCADA.

8 topics8 written guides

Written guides in this section

Full references, procedures, and diagnostic guides published under Communications.

ReferenceCommunicationsEthernet

EtherNet/IP

How EtherNet/IP moves control data: CIP over standard Ethernet, implicit I/O connections on a requested packet interval, explicit messaging, producer and consumer tags, and what the network has to provide.

9 min readUpdated Sep 5, 2026

ReferenceCommunicationsTelemetry

DNP3

The protocol built for utility telemetry: master and outstation, static and event data classes, unsolicited reporting, time-stamped events, and why it suits slow links that Modbus does not.

8 min readUpdated Sep 5, 2026

ReferenceCommunicationsSCADA

OPC UA

What OPC UA is for, how its information model, security, and transports differ from OPC Classic, where it belongs in a plant, and what to check before relying on it.

8 min readUpdated Sep 5, 2026

ReferenceCommunicationsModbus

Serial Communications

RS-232, RS-422, and RS-485 in practice: which is which, cable and distance, termination, biasing, the common reference wire everyone leaves off, and the settings that have to match at both ends.

9 min readUpdated Sep 5, 2026

ReferenceCommunicationsModbus

Protocol Gateways

Protocol converters between a controller and devices that do not speak its language: what a gateway does, the common pairings in water and wastewater, the mapping table that is the whole configuration, the failure modes a gateway adds, and when to use a native interface instead.

9 min readUpdated Sep 5, 2026

ReferenceCommunicationsPLC

Remote I/O

Extending controller I/O to another panel or another site over a network: the adapter and the rack, the update rate and what it costs, what the outputs do when the link fails, the difference between remote I/O and a remote controller, and the wiring, addressing, and diagnostics that make it dependable.

9 min readUpdated Sep 5, 2026

Topics in this area

Direct contact

Have a controls question?

Reach Eric Sullivan directly about anything on this site, a controls or automation topic, or one of his personal projects.

References to manufacturers, products, model numbers, software platforms, technical specifications, companies, standards organizations, or other organizations are provided for informational purposes and do not imply sponsorship, endorsement, authorization, or affiliation unless expressly stated. Manufacturer specifications must be independently verified against current manufacturer documentation.