HMI Design
Building operator displays people can actually run a plant from.
Written guides in this section
Full references, procedures, and diagnostic guides published under HMI Design.
ISA-101: Human Machine Interfaces
What the ISA-101 standard for human machine interfaces covers, its lifecycle from philosophy to maintenance, the display hierarchy, and what adopting it changes on a project.
8 min readUpdated Sep 5, 2026
HMI Navigation
How operators move through the displays: the display hierarchy from overview to detail, a fixed navigation bar with area alarm indication, one-click paths from an alarm to the device, the rules that keep any display within two clicks, and what to leave out.
9 min readUpdated Sep 5, 2026
Color in HMI Design
How color is used on a high performance HMI: a gray palette for normal operation so that color means something, alarm colors reserved by priority, equipment state by fill and text rather than red and green, color-blind safe choices, and the palette table.
9 min readUpdated Sep 5, 2026
Alarm Indication on the HMI
How an alarm looks and sounds on the operator screen: the ISA-101 and ISA-18.2 rules for color, shape, and blink, the alarm banner and summary, acknowledgment behavior, navigation to the alarm, and indication that survives colorblindness and a noisy control room.
10 min readUpdated Sep 5, 2026
Situational Awareness
Designing displays so an operator knows what is happening, what it means, and what comes next: the three levels of awareness, the display hierarchy, analog indicators with normal ranges, embedded trends, time-to-limit predictions, and a test for any display.
10 min readUpdated Sep 5, 2026
HMI Faceplates
The pop-up that controls one device: what a pump, valve, or loop faceplate must show, the mode and command layout, interlock and permissive display, security by role, and building faceplates from a standard object so every device behaves the same.
10 min readUpdated Sep 5, 2026
Topics in this area
ISA-101
The human-machine interface standard: lifecycle, style guides, and design consistency.
High Performance HMI
Grey backgrounds, reserved color, and displays built for detecting abnormal conditions rather than decoration.
Navigation
Navigation — practical reference notes for controls engineers, integrators, and technicians working with hmi design.
Colors
Colors — practical reference notes for controls engineers, integrators, and technicians working with hmi design.
Alarm Indication
Alarm Indication — practical reference notes for controls engineers, integrators, and technicians working with hmi design.
Situational Awareness
Situational Awareness — practical reference notes for controls engineers, integrators, and technicians working with hmi design.
Faceplates
Faceplates — practical reference notes for controls engineers, integrators, and technicians working with hmi design.
Trends
Trends — practical reference notes for controls engineers, integrators, and technicians working with hmi design.
Direct contact
Have a controls question?
Reach Eric Sullivan directly about anything on this site, a controls or automation topic, or one of his personal projects.
References to manufacturers, products, model numbers, software platforms, technical specifications, companies, standards organizations, or other organizations are provided for informational purposes and do not imply sponsorship, endorsement, authorization, or affiliation unless expressly stated. Manufacturer specifications must be independently verified against current manufacturer documentation.