Controls › Control Panels

Panel Design

Designing a panel that passes inspection and survives the field.

9 topics9 written guides

Written guides in this section

Full references, procedures, and diagnostic guides published under Panel Design.

ReferenceUL 508APanels

UL 698A

Industrial control panels for hazardous locations: what UL 698A adds to UL 508A, a panel in a classified area or a safe-area panel with intrinsically safe circuits, barriers and isolators, the control drawing, and where utilities meet classified areas.

8 min readUpdated Sep 5, 2026

ReferenceNECPanels

NFPA 70 and the Control Panel

The National Electrical Code inside an industrial control panel: Article 409 and the listing it points to, the short-circuit current rating, overcurrent protection for control circuits, grounding and bonding, working space, and what an inspector asks.

9 min readUpdated Sep 5, 2026

ReferencePanelsUL 508A

Short-Circuit Current Rating (SCCR)

What a control panel’s short-circuit current rating means, how it is determined under UL 508A, why the NEC requires it on the label, and why the number is usually smaller than people expect.

9 min readUpdated Sep 5, 2026

ReferencePanelsDesign

Enclosure Selection

Choosing the box: NEMA and UL 50 type ratings, materials for corrosive and outdoor sites, sizing for heat and wire bending space, and the details at the conduit entries and the door that decide whether the rating survives installation.

8 min readUpdated Sep 5, 2026

ReferencePanelsDesign

Enclosure Heat Calculations

Estimating the temperature inside a control panel from the power its contents dissipate and the surface that carries it out, what to do when the answer is too hot, and why drives change everything.

8 min readUpdated Sep 5, 2026

ReferencePanelsDesign

Component Layout

Arranging a panel so it is safe to work in, cool enough to run, quiet enough for its signals, and possible to modify: power and control separation, heat, wireways, terminals, and the working space rules.

8 min readUpdated Sep 5, 2026

Topics in this area

Direct contact

Have a controls question?

Reach Eric Sullivan directly about anything on this site, a controls or automation topic, or one of his personal projects.

References to manufacturers, products, model numbers, software platforms, technical specifications, companies, standards organizations, or other organizations are provided for informational purposes and do not imply sponsorship, endorsement, authorization, or affiliation unless expressly stated. Manufacturer specifications must be independently verified against current manufacturer documentation.