Water & Wastewater › Water Systems
Water Treatment
From the source to the distribution system, and the controls at each step.
Written guides in this section
Full references, procedures, and diagnostic guides published under Water Treatment.
Raw Water
Controlling the front of a surface water plant: intake and screens, low-lift pumping, the raw water flow that paces the whole plant, the online quality instruments that warn of a changing source, and the alarms and ramp limits that keep the train stable.
9 min readUpdated Sep 5, 2026
Wells
Operating a wellfield as a water source: selecting and rotating wells, pump-to-waste on start, drawdown and specific capacity, wellhead chemical feed, blending for nitrate or arsenic, the telemetry a well needs, and the interlocks that protect the pump.
10 min readUpdated Sep 5, 2026
Aeration
Aeration in drinking water treatment: stripping carbon dioxide, hydrogen sulfide, radon, and volatile organics, and oxidizing iron and manganese ahead of filtration. The aerator types, what each needs from the control system, the pH shift, and the interlocks.
9 min readUpdated Sep 5, 2026
Filtration
Controlling gravity and pressure filters: effluent rate and level control, head loss and turbidity on every filter, the backwash triggers and sequence, filter-to-waste and ripening, the turbidity rules that filter monitoring answers to, and the operator view.
11 min readUpdated Sep 5, 2026
Chemical Feed
Chemical feed from the control side: the chemicals and where they go, metering pumps and dry feeders, flow pacing with residual trim, the dose arithmetic, day tanks and drawdown tests, loss-of-feed detection, interlocks, and overfeed protection.
11 min readUpdated Sep 5, 2026
Disinfection Control
Controlling chlorine and chloramine dosing at a water plant: the CT concept and how contact time is credited, flow-paced and residual-trimmed feed, gas, hypochlorite, and on-site generation systems, the point-of-entry residual as the compliance measurement, and the interlocks that stop a feed system from over- or under-dosing.
11 min readUpdated Sep 5, 2026
Topics in this area
Raw Water
Raw Water — practical reference notes for controls engineers, integrators, and technicians working with water treatment.
Wells
Wells — practical reference notes for controls engineers, integrators, and technicians working with water treatment.
Aeration
Aeration — practical reference notes for controls engineers, integrators, and technicians working with water treatment.
Filtration
Filtration — practical reference notes for controls engineers, integrators, and technicians working with water treatment.
Chemical Feed
Chemical Feed — practical reference notes for controls engineers, integrators, and technicians working with water treatment.
Disinfection
Disinfection — practical reference notes for controls engineers, integrators, and technicians working with water treatment.
Storage
Storage — practical reference notes for controls engineers, integrators, and technicians working with water treatment.
High Service Pumping
High Service Pumping — practical reference notes for controls engineers, integrators, and technicians working with water treatment.
Direct contact
Have a controls question?
Reach Eric Sullivan directly about anything on this site, a controls or automation topic, or one of his personal projects.
References to manufacturers, products, model numbers, software platforms, technical specifications, companies, standards organizations, or other organizations are provided for informational purposes and do not imply sponsorship, endorsement, authorization, or affiliation unless expressly stated. Manufacturer specifications must be independently verified against current manufacturer documentation.