Cybersecurity

Network Segmentation

Separating the control network from everything else.

5 topics5 written guides

Written guides in this section

Full references, procedures, and diagnostic guides published under Network Segmentation.

ReferenceCybersecurityNetworking

Zones and Conduits

The IEC 62443 way to segment a control system: grouping assets into zones with a shared security level, inventorying every conduit between them, and turning the drawing into firewall rules. With a worked water utility example.

12 min readUpdated Sep 5, 2026

ReferenceCybersecurityNetworking

VLAN Segmentation

Using VLANs to build the zones of a control network on shared switches: what a VLAN separates and what it does not, the zone-to-VLAN mapping, trunks and the native VLAN, routing only through a firewall, and where separate hardware begins.

9 min readUpdated Sep 5, 2026

ReferenceCybersecurityNetworking

Industrial DMZ Design

The buffer zone between the business network and the control system: what goes in it, the no-direct-path rule, push-not-pull data flows, the firewall pair, and the services a utility actually needs to place there.

10 min readUpdated Sep 5, 2026

ReferenceCybersecurityNetworking

Data Diodes

Hardware that lets data flow one way only, from the control network outward, with no physical return path: what a data diode and a unidirectional gateway are, where they belong, what they can and cannot carry, and when a firewall is enough instead.

8 min readUpdated Sep 5, 2026

ReferenceCybersecurityTelemetry

Segmenting a Remote Site

A lift station, a well, or a tank site as its own zone: the site firewall and what it permits, the modem as transport with no public address, cameras and extras off the control segment, engineering access through the plant, and local control without the link.

9 min readUpdated Sep 5, 2026

Topics in this area

Direct contact

Have a controls question?

Reach Eric Sullivan directly about anything on this site, a controls or automation topic, or one of his personal projects.

References to manufacturers, products, model numbers, software platforms, technical specifications, companies, standards organizations, or other organizations are provided for informational purposes and do not imply sponsorship, endorsement, authorization, or affiliation unless expressly stated. Manufacturer specifications must be independently verified against current manufacturer documentation.