Troubleshooting

Communications Troubleshooting

Communications Troubleshooting in industrial control systems — covering 5 topic areas in the CurryControls.com controls and automation knowledge hub.

5 topics5 written guides

Written guides in this section

Full references, procedures, and diagnostic guides published under Communications Troubleshooting.

TroubleshootingTroubleshootingCommunications

Device Times Out

A polled device that answers late or not at all: how to read the driver counters, tell a dead device from a slow one, and find the timeout setting, the bus loading, the radio latency, the duplicate address, or the device that is simply too busy to answer.

9 min readUpdated Sep 5, 2026

TroubleshootingTroubleshootingModbus

Read Works but Write Fails

Polling a device returns good data and writing a setpoint does nothing or returns an exception: a write-protected device, a read-only register, the wrong function code, a wrong address or type, logic that overwrites the value, a security rule, or a local mode.

8 min readUpdated Sep 5, 2026

TroubleshootingTroubleshootingModbus

Wrong Register Data

The poll succeeds and the numbers are nonsense: an offset by one, the wrong table, swapped words in a 32-bit value, a float read as an integer, signed read as unsigned, a scale factor not applied, a stale gateway value, or the wrong unit answering.

8 min readUpdated Sep 5, 2026

TroubleshootingTroubleshootingCommunications

Protocol Gateway Stops Passing Data

The gateway is powered and pingable and the data behind it is frozen or gone: the device side failed while the master side answers, a stalled gateway, configuration lost on a power cycle, a stale mapping, or a master polling too fast. Testing each side.

8 min readUpdated Sep 5, 2026

TroubleshootingTroubleshootingModbus

Modbus Device Intermittently Offline

A device that answers most of the time. Termination, bias, timing, and the physical layer details that produce a bus which almost works.

9 min readUpdated Aug 21, 2026

Topics in this area

Direct contact

Have a controls question?

Reach Eric Sullivan directly about anything on this site, a controls or automation topic, or one of his personal projects.

References to manufacturers, products, model numbers, software platforms, technical specifications, companies, standards organizations, or other organizations are provided for informational purposes and do not imply sponsorship, endorsement, authorization, or affiliation unless expressly stated. Manufacturer specifications must be independently verified against current manufacturer documentation.