The short answer
ISA Standards for Controls
ISA publishes the standards that define how control systems are drawn, tagged, alarmed, displayed, and secured. The ones a utility or an integrator uses most are ISA-5.1 for instrumentation symbols and tag numbering on P&IDs, ISA-18.2 for alarm management, ISA-101 for HMI design, ISA-20 for instrument specification forms, and the ISA-99 work that became the IEC 62443 security series. They are consensus documents, purchased from ISA, and they are cited in specifications so that everyone on a project draws, names, and designs the same way.
Key points
- ISA-5.1 is why a level transmitter is LIT-101 on every drawing. Cite it in every specification.
- ISA-18.2 defines the alarm management lifecycle; ISA-101 defines HMI design. Both are widely adopted in water.
- ISA-20 gives the specification sheet forms for instruments and control valves.
- ISA-99 is the origin of IEC 62443; the security series is now referenced by its IEC number.
- Standards are purchased and cited by edition. A specification that cites one without an edition cites nothing.
What ISA is
The International Society of Automation is the professional society for automation and control practitioners, and its standards committees produce the consensus documents the profession works from. ISA standards are American National Standards through ANSI, and several have become international standards through IEC. They are written by committees of users, integrators, and vendors, revised on a cycle, and sold by ISA; a project that uses them purchases them, and a specification that cites them names the edition.
The standards a utility project uses
| Standard | Title | What it is used for | Where on this site |
|---|---|---|---|
| ISA-5.1 | Instrumentation Symbols and Identification | The tag letter codes and the graphic symbols on P&IDs and loop drawings; the reason FIT means flow indicating transmitter everywhere | P&ID drawings; instrument lists |
| ISA-5.4 | Instrument Loop Diagrams | The content and format of loop drawings | Instrument lists; loop checks |
| ISA-18.2 | Management of Alarm Systems for the Process Industries | The alarm lifecycle: philosophy, rationalization, design, monitoring; the definitions of an alarm, priority, floods, and states | ISA-18.2; alarm philosophy; rationalization; alarm floods |
| ISA-101 | Human Machine Interfaces for Process Automation Systems | HMI design: display hierarchy, style guide, color use, alarm indication, navigation | ISA-101; high-performance HMI; faceplates; navigation |
| ISA-20 | Specification Forms for Process Measurement and Control Instruments | The data sheet forms used to specify transmitters, switches, analyzers, and control valves | Instrument lists |
| ISA-88 | Batch Control | The models and terminology for batch and recipe control; also the source of the equipment module and phase concepts used in sequence programming | State machines; sequences of operation |
| ISA-95 | Enterprise-Control System Integration | The levels model and the interface between control systems and business systems; the origin of the level numbering the Purdue model uses | Purdue model; historian architecture |
| ISA-99 / IEC 62443 | Industrial Automation and Control Systems Security | The security series, now published as IEC 62443 and referenced by that number | IEC 62443 |
| ISA-84 / IEC 61511 | Functional Safety: Safety Instrumented Systems | Safety instrumented systems for the process sector; relevant to chlorine gas systems and a few other utility applications | Interlocks |
| ISA-71 | Environmental Conditions for Process Measurement and Control Systems | Classification of environments, including corrosive atmospheres such as hydrogen sulfide, for specifying equipment | Enclosure selection |
| The ISA-12 series | Hazardous location practices, including intrinsic safety | Instrument installation in classified areas | Headworks |
How they are used on a project
- In specifications
- The engineer cites the standards the work must follow: ISA-5.1 for tags and symbols, ISA-18.2 for the alarm system, ISA-101 for the HMI, ISA-20 for the data sheets. The citation makes the standard a contract requirement, and the edition is named so that everyone reads the same document.
- In site standards
- A utility writes its tag convention, its HMI style guide, and its alarm philosophy as documents that apply the ISA standards to its own system. The standards give the framework; the site documents give the decisions.
- In training
- ISA courses and certifications, including the Certified Automation Professional and the Certified Control Systems Technician, are built on the standards and are the common credentials in the field.
- In assessment
- An alarm system is benchmarked against the ISA-18.2 metrics; an HMI is reviewed against ISA-101; a security program is assessed against 62443. The standards are the yardsticks.
Getting them
ISA standards are purchased from ISA directly or through standards resellers, individually or by subscription, and ISA members receive a discount. The free material is substantial: ISA publishes summaries, articles, and quick-start guides, the technical report abstracts describe what each report covers, and the InTech magazine and ISA blogs discuss application. A utility that will implement ISA-18.2 and ISA-101 seriously buys both standards and their technical reports; one that wants the vocabulary can start with the free summaries and the pages on this site.
Frequently asked questions
- Do we have to follow ISA standards?
- Only where a specification, a contract, or a regulation cites them. No law requires ISA-101 for a water plant HMI. Following them is how a utility gets a system that any integrator can work on and that matches the practice of the profession, which is why specifications cite them.
- What is the difference between ISA-99 and IEC 62443?
- The same work. ISA-99 is the ISA committee that developed the security series and the original numbering; the standards are published jointly as ISA/IEC 62443 and referenced by the IEC number. The committee continues as ISA99.
- Which ISA-5.1 edition should we use?
- The current one, cited by year in the specification and the site tag standard. The 2009 revision made significant changes to the letter table and the symbols from the 1984 version that much of the installed base was drawn under; a site with older drawings decides whether to redraw or to carry both conventions with a note.
- Are there ISA standards for water specifically?
- No. ISA standards are process-industry generic, and water and wastewater apply them like any other process. The water sector has its own bodies, AWWA and WEF, whose manuals of practice reference ISA where control systems are involved.
Related topics
- ISA-18.2 Alarm ManagementThe lifecycle standard for alarm systems, the rate targets that define a workable system, and why alarm rationalization is the step nobody wants to fund.
- ISA-101: Human Machine InterfacesWhat the ISA-101 standard for human machine interfaces covers, its lifecycle from philosophy to maintenance, the display hierarchy, and what adopting it changes on a project.
- How to Read a P&IDWhat a piping and instrumentation diagram shows, how ISA-5.1 tag bubbles and line types encode the control system, and how to trace a loop across sheets.
- IEC 62443The international standard series for industrial automation and control system security: how it is organized, what security levels and foundational requirements mean, and how a utility or integrator actually uses it.
- Instrument ListsThe index of every measuring and final control device on a project: what the instrument list records, how it grows from the P&ID into specification sheets and calibration records, the columns that matter at each stage, and how it becomes the asset register the utility maintains.
- The Alarm PhilosophyThe document that decides what is allowed to be an alarm: the definition, the criteria, the priorities and their meaning, the performance targets, the handling rules, and who owns it. Under ISA-18.2 it comes first.