Controls › SCADA & HMI

Alarm Management

Making an alarm system that operators trust instead of silence.

8 topics8 written guides

Written guides in this section

Full references, procedures, and diagnostic guides published under Alarm Management.

ReferenceSCADAAlarms

The Alarm Philosophy

The document that decides what is allowed to be an alarm: the definition, the criteria, the priorities and their meaning, the performance targets, the handling rules, and who owns it. Under ISA-18.2 it comes first.

9 min readUpdated Sep 5, 2026

ReferenceAlarmsSCADA

Alarm Priority

How to assign alarm priorities that operators trust: a consequence-and-time matrix, three or four levels, the target distribution from ISA-18.2 and EEMUA 191, and the mistakes that make every alarm high.

9 min readUpdated Sep 5, 2026

ReferenceAlarmsSCADA

Alarm Rationalization

The meeting where every alarm earns its place: who attends, what is decided for each alarm, how to document it in a master alarm database, and how to run it at a utility that cannot spare a week.

10 min readUpdated Sep 5, 2026

ReferenceAlarmsSCADA

Alarm Shelving

The operator tool for temporarily silencing a nuisance alarm: what shelving is and is not, the rules a philosophy sets, who may shelve what and for how long, automatic unshelving, the shelved list, the record, and how to implement it on any platform.

8 min readUpdated Sep 5, 2026

ReferenceAlarmsSCADA

Alarm Suppression

Suppressing alarms by design: state-based logic that removes alarms that mean nothing in the current state, parent-child logic that stops a flood at its source, out-of-service suppression for maintenance, the rules that keep it safe, and how to test it.

9 min readUpdated Sep 5, 2026

ReferenceAlarmsSCADA

Alarm Floods

What an alarm flood is, why it happens at exactly the wrong moment, the ISA-18.2 rate targets, and the design measures that keep a power failure or a communication loss from burying the one alarm that matters.

10 min readUpdated Sep 5, 2026

Topics in this area

Direct contact

Have a controls question?

Reach Eric Sullivan directly about anything on this site, a controls or automation topic, or one of his personal projects.

References to manufacturers, products, model numbers, software platforms, technical specifications, companies, standards organizations, or other organizations are provided for informational purposes and do not imply sponsorship, endorsement, authorization, or affiliation unless expressly stated. Manufacturer specifications must be independently verified against current manufacturer documentation.