Troubleshooting
Grounding Troubleshooting
Grounding Troubleshooting in industrial control systems — covering 5 topic areas in the CurryControls.com controls and automation knowledge hub.
Written guides in this section
Full references, procedures, and diagnostic guides published under Grounding Troubleshooting.
Ground Loop Symptoms
How a ground loop shows itself: hum on analog signals, offsets that change when large loads switch, serial links that error, and readings that differ by location. The mechanism, the measurements that prove it, and fixes that never lift a safety ground.
9 min readUpdated Sep 5, 2026
Floating Reference Between Panels
Signals between two panels that misbehave because the panels do not share a DC reference: inputs that never turn on or half turn on, strange voltages to ground, and noise that comes and goes. How DC commons should be bonded and how to cross a panel boundary.
9 min readUpdated Sep 5, 2026
Shield Grounded at Both Ends
A shield connected to ground at the panel and again in the field becomes a conductor between two grounds, and its current becomes noise on the pair inside. How to find the second connection, what to measure before lifting it, and when both ends are correct.
8 min readUpdated Sep 5, 2026
Missing Equipment Ground
An enclosure, motor, or device with no effective equipment ground: how it shows up as a tingle, a fault that does not trip, surge protection that does nothing, or instrument noise; how to test the path safely; and why a ground rod is no substitute.
9 min readUpdated Sep 5, 2026
High Neutral-to-Ground Voltage
What a neutral-to-ground voltage reading means, the values that are normal, and the causes of a high one: a long or heavily loaded neutral, harmonic current, a loose or open neutral, a missing service bond, or an extra bond downstream, and telling them apart.
9 min readUpdated Sep 5, 2026
Topics in this area
Ground Loop Symptoms
Ground Loop Symptoms — practical reference notes for controls engineers, integrators, and technicians working with grounding troubleshooting.
Floating Reference Between Panels
Floating Reference Between Panels — practical reference notes for controls engineers, integrators, and technicians working with grounding troubleshooting.
Shield Grounded At Both Ends
Shield Grounded At Both Ends — practical reference notes for controls engineers, integrators, and technicians working with grounding troubleshooting.
Missing Equipment Ground
Missing Equipment Ground — practical reference notes for controls engineers, integrators, and technicians working with grounding troubleshooting.
High Neutral To Ground Voltage
High Neutral To Ground Voltage — practical reference notes for controls engineers, integrators, and technicians working with grounding troubleshooting.
Direct contact
Have a controls question?
Reach Eric Sullivan directly about anything on this site, a controls or automation topic, or one of his personal projects.
References to manufacturers, products, model numbers, software platforms, technical specifications, companies, standards organizations, or other organizations are provided for informational purposes and do not imply sponsorship, endorsement, authorization, or affiliation unless expressly stated. Manufacturer specifications must be independently verified against current manufacturer documentation.