How-To

SCADA How-To

SCADA How-To in industrial control systems — covering 7 topic areas in the CurryControls.com controls and automation knowledge hub.

7 topics7 written guides

Written guides in this section

Full references, procedures, and diagnostic guides published under SCADA How-To.

How-ToHow-ToSCADA

How to Build a Tag

Create a SCADA tag that is correct, documented, and consistent with every other tag: name it by the convention, bind it to the right controller address or name, and verify it against the live value and the I/O list before it goes on a screen.

7 min readUpdated Sep 5, 2026

How-ToHow-ToSCADA

How to Configure Alarms

Configure alarms in the SCADA system from the alarm list: set the source, controller-generated or evaluated in SCADA, the limits and deadband and delay, and the notification; then test each alarm end to end and review the alarm rate after the first weeks.

8 min readUpdated Sep 5, 2026

How-ToHow-ToSCADA

How to Trend Data

Build trends that operators use: choose the tags that tell one story per trend, set scales and time spans that show the behavior, and make ad hoc trending fast enough that an operator reaches for it before a phone call.

7 min readUpdated Sep 5, 2026

How-ToHow-ToSCADA

How to Configure a Historian

Set up a process historian that collects what matters and keeps it: decide the tags and their classes, set collection intervals and deadbands per class, size the storage and the retention, and hand the operators a working trend on day one.

8 min readUpdated Sep 5, 2026

How-ToSCADATroubleshooting

How to Diagnose a Bad Quality Tag

Trace a bad quality indication from the SCADA screen back to its source: the tag configuration, the driver and device connection, the controller tag, and the field signal, using the diagnostics each layer provides, and separate a stale value from a bad one.

8 min readUpdated Sep 5, 2026

How-ToHow-ToHMI

How to Build Pump Graphics

Build a pump symbol and faceplate that operators can read at a glance and use without error: a symbol that shows state by shape and a muted palette with color reserved for abnormal, and a test against the high-performance HMI principles before it is deployed.

8 min readUpdated Sep 5, 2026

Topics in this area

Direct contact

Have a controls question?

Reach Eric Sullivan directly about anything on this site, a controls or automation topic, or one of his personal projects.

References to manufacturers, products, model numbers, software platforms, technical specifications, companies, standards organizations, or other organizations are provided for informational purposes and do not imply sponsorship, endorsement, authorization, or affiliation unless expressly stated. Manufacturer specifications must be independently verified against current manufacturer documentation.