Controls › SCADA & HMI
SCADA Troubleshooting
What to check when the screen stops matching the plant.
Written guides in this section
Full references, procedures, and diagnostic guides published under SCADA Troubleshooting.
Frozen Values
Why a SCADA value stops changing while looking normal: the five layers where it can freeze, from a transmitter holding its output to a client that lost its server, how to find the layer by comparing each, and the heartbeat that makes a freeze announce itself.
9 min readUpdated Sep 5, 2026
Lost Communications
What should happen when SCADA loses a device, a site, or everything, how the pattern tells which, the diagnostic order from the server outward through network, firewall, medium, and site, and the design that makes a lost link an alarm rather than an incident.
9 min readUpdated Sep 5, 2026
Bad Quality
What a quality flag means and where it comes from: good, uncertain, and bad with substatus codes, how quality propagates from device through driver, tag, display, alarm, and historian, the causes by layer, and the rule that a bad value is never a number.
9 min readUpdated Sep 5, 2026
Server Failure
How SCADA servers fail and what to do when one does: failure modes from a full disk to a dead hypervisor host, what the plant experiences with and without redundancy, the recovery sequence from restore to alarm verification, and the monitoring that warns.
9 min readUpdated Sep 5, 2026
Client Problems
Diagnosing the operator station rather than the system: a client that will not connect, shows nothing, runs slowly, freezes, or stays silent on an alarm, with the causes, the order of checks, and the standard build and spare that make the fix a swap.
8 min readUpdated Sep 5, 2026
Historian Problems
How a historian goes wrong and how to find each fault: gaps, wrong values, detail never stored, disks that fill, slow queries, backfill that never arrives, and unreadable archives, with the collector, queue, configuration, and storage checks that locate it.
9 min readUpdated Sep 5, 2026
Topics in this area
Frozen Values
Frozen Values — practical reference notes for controls engineers, integrators, and technicians working with scada troubleshooting.
Lost Communications
Lost Communications — practical reference notes for controls engineers, integrators, and technicians working with scada troubleshooting.
Bad Quality
Bad Quality — practical reference notes for controls engineers, integrators, and technicians working with scada troubleshooting.
Server Failure
Server Failure — practical reference notes for controls engineers, integrators, and technicians working with scada troubleshooting.
Client Problems
Client Problems — practical reference notes for controls engineers, integrators, and technicians working with scada troubleshooting.
Historian Problems
Historian Problems — practical reference notes for controls engineers, integrators, and technicians working with scada troubleshooting.
Alarm Problems
Alarm Problems — practical reference notes for controls engineers, integrators, and technicians working with scada troubleshooting.
Time Synchronization
Time Synchronization — practical reference notes for controls engineers, integrators, and technicians working with scada troubleshooting.
Direct contact
Have a controls question?
Reach Eric Sullivan directly about anything on this site, a controls or automation topic, or one of his personal projects.
References to manufacturers, products, model numbers, software platforms, technical specifications, companies, standards organizations, or other organizations are provided for informational purposes and do not imply sponsorship, endorsement, authorization, or affiliation unless expressly stated. Manufacturer specifications must be independently verified against current manufacturer documentation.