Controls › Instrumentation

Analytical

Water quality instrumentation and the maintenance it demands.

8 topics8 written guides

Written guides in this section

Full references, procedures, and diagnostic guides published under Analytical.

ReferenceInstrumentationWater

pH Measurement

Glass electrodes, reference junctions, and why pH is the measurement that drifts: how the sensor works, temperature compensation, two-point buffer calibration, mounting rules, the failure modes of the reference, and using the signal for chemical feed control.

11 min readUpdated Sep 5, 2026

ReferenceInstrumentationWater

ORP

Oxidation-reduction potential: what the millivolt reading means and does not, the platinum and reference pair, uses in dechlorination control, disinfection indication, anoxic monitoring, and chemical treatment, checking with standards, and electrode drift.

7 min readUpdated Sep 5, 2026

ReferenceInstrumentationWater

Chlorine Residual Analyzers

Amperometric and colorimetric residual analyzers: what each measures, free versus total chlorine, pH and flow dependence, sample line design, calibration against a DPD grab sample, and using the signal for feed control.

11 min readUpdated Sep 5, 2026

ReferenceInstrumentationWater

Turbidity Measurement

Nephelometric turbidimeters for filter effluent and raw water: how 90-degree scattering is measured, the methods and the NTU, low-range versus high-range instruments, bubbles and the debubbler, formazin calibration and verification standards, and the compliance record the instrument exists to produce.

11 min readUpdated Sep 5, 2026

ReferenceInstrumentationWater

Conductivity

Conductivity measurement in water systems: what it indicates, contacting and inductive sensors, cell constants and ranges, temperature compensation, the relation to total dissolved solids, uses from membrane monitoring to blending, and fouling problems.

8 min readUpdated Sep 5, 2026

ReferenceInstrumentationWastewater

Dissolved Oxygen Measurement

Optical and membrane DO sensors for aeration control: how each measures, why optical has taken over, air calibration with pressure and salinity corrections, sensor placement in an aeration basin, fouling and cleaning, and the response time that limits the control loop.

11 min readUpdated Sep 5, 2026

Topics in this area

Direct contact

Have a controls question?

Reach Eric Sullivan directly about anything on this site, a controls or automation topic, or one of his personal projects.

References to manufacturers, products, model numbers, software platforms, technical specifications, companies, standards organizations, or other organizations are provided for informational purposes and do not imply sponsorship, endorsement, authorization, or affiliation unless expressly stated. Manufacturer specifications must be independently verified against current manufacturer documentation.